MS1-9-12-230-1-1CG-A-0DB [Carling Technologies]
Magnetic Circuit Breaker;型号: | MS1-9-12-230-1-1CG-A-0DB |
厂家: | Carling Technologies |
描述: | Magnetic Circuit Breaker 电路保护 |
文件: | 总8页 (文件大小:3157K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
MS-Series
MS-Series
CIRCUIT BREAKER
Designed and tested to operate flawlessly in the harshest of environments, the MS-Series sealed toggle circuit
breaker is ideally suited for COTS (commercial off the shelf) military applications. Our space saving envelope
meets IP68 requirements and features a durable metal and sealed mounting bushing with MIL-PRF-39019F
ingress protection when mounted in a panel.
This class-leading, affordable circuit breaker was designed in accordance with the requirements of MIL-
PRF-55629 and MIL STD 202, making it the best choice for those applications where shock, vibration, moisture
resistance, salt spray and thermal shock are of the utmost consideration. The MS-Series’ compact size and
reliability make it ideal for crucial communication equipment and other mission critical components.
1-3 poles; 0.02-30 amps; 65VDC, 240VAC, 120/240VAC; UL, cUL recognized & TUV pending.
Eco-Friendly
Resources:
Download 3D CAD Files
IGS
STP
Watch Product Video
Product Highlights:
Sealed Toggle Actuator
Typical Applications:
COTS Military
MIL-PRF-39019F Ingress Protection
ꢀ •ꢀ CommunicationꢀEquipment
MIL-PRF-55629 and MIL STD 202
OffꢀHighwayꢀEquipment
Compliant
Compact Design
ꢀ ꢀ•ꢀ Construction,ꢀMiningꢀ&ꢀAgricultureꢀꢀ
Generatorsꢀ&ꢀPowerꢀSupplies
HarshꢀEnvironmentꢀApplicationsꢀ
Carling Technologies, Inc.
60 Johnson Avenue, Plainville, CT 06062
Email: sales@carlingtech.com
Application Support: team2@carlingtech.com
Phone: 860.793.9281 Fax: 860.793.9231
www.carlingtech.com
|
2
MS-Series Circuit Breaker - Design Features
MS-Series
DESIGN FEATURES
SEALS
COMPACT SIZE
Max performance in compact size: 0.20-30
Amps; 65 VDC, 240 VAC 120/240 VAC
IP68 Designed and tested to comply
with MIL-PRF-39019F Ingress Protection
1.375 in
[34.93 mm]
0.65 in
[16.51 mm]
2.158 in
[54.81 mm]
TERMINAL BARRIERS
Meet UL 1077 Spacing Requirements
OPTIONAL AUXILIARY SWITCH
Provides Breaker Status Indication
Email: sales@carlingtech.com Application Support: team2@carlingtech.com
Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com
|
MS-Series Circuit Breaker - General Specifications
3
Electrical Tables
Table A: Lists UL & cUL Configuration & Performance Capabilities
MS-SERIES TABLE A: COMPONENT SUPPLEMENTARY PROTECTORS
Short Circuit
Voltage
Current Rating
Capacity (Amps)1
UL / cUL
Circuit Configuration Max Rating Frequency Phase General Purpose Amps Poles Breaking
U1
U3
65
240
120 / 240
DC
50 / 60
50 / 60
---
1
1
0.02 - 30
0.02 - 30
0.02 - 30
1
3000
2000
2000
300
300
300
Series
1, 2
2 or 3
Notes:
1
Short Circuit Current Rating (SC) Codes — The short-circuit current rating, followed by a letter and number designating the test conditions
ꢀ
andꢀanyꢀcalibrationꢀfollowingꢀtheꢀshort-circuitꢀtestꢀasꢀdefinedꢀbelow:
U - Indicates that the short circuit test was performed without a series fuse
1 - Indicates that a re-calibration was not performed as part of the short circuit testing
3 - Indicates that the protector has proven to be suitable for further use after the short circuit test
Re-calibration, dielectric strength and voltage withstand tests were performed after the short circuit testing
Mechanical
Electrical
Current Ratings
10,000 On-Off operations @ 6 per
minute with rated current and
voltage.
Trips on short circuit and
overload, even when the actuator
is forcibly held in the “On”
position.
The operating handle moves
positively to the “Off” position
when a short circuit or overload
causes the circuit breaker to trip.
Current Ratings
.02 - 30 Amps
65VDC, 240VAC, 120/240VAC
See Table A
5A @ 125VAC,
3A @ 32VDC,
.1A @ 125VAC, 32VDC
UL,CSA 1500V, 50/60 Hz for one
minute between all electrically
isolated terminals.
Minimum of 100 Megohms @
500VDC
Voltage Rating
Short Circuit Rating
Auxiliary Switch Rating
Trip Free
Dielectric Strength
Trip Indication
Insulation Resistance
Time Delay
Impedance
See delay curve
Environmental
Designedꢀinꢀaccordanceꢀwithꢀrequirementsꢀofꢀspecificationꢀ
MIL PRF-55629 & MIL-STD-202G as follows:
0.20 - 30.0
25%
Shock
Withstands 100G’s, 6ms, saw
tooth while carrying rated current
per Method 213, Condition I.
Instantaneous curves tested at
80% of rated current.
Vibration
Withstands 0.060” excursion from
10-55 Hz, and 10G’s 55-500 Hz,
at rated current per Method
204C, Test Condition A.
Instantaneous curves tested at
80% of rated current.
Method 101, Condition A (90-
95% RH @ 5% NaCl Solution, 96 hrs)
Method 106G
Method 107D, Condition A (Five
cycles @ -55°C to +25°C to
+85°C to +25°C
Salt Spray
Moisture Resistance
Thermal Shock
Physical
Number of Poles
Weight
1-3 poles
Approximately 1.8 oz (50 G) per
pole
Operating Temperature
Ingress Protection Level MIL-PRF-55629C when mounted
in panel.
-40°C to +85°C
Dimensionsꢀ
Seeꢀformꢀ&ꢀfitꢀdrawing
Other
Materials used in this product
are non-nutrient to fungus
growth.
Agency Certifications
UL Standard 1077
CUL Standard C22.2
*Manufacturer reserves the right to change product specification without prior notice.
Email: sales@carlingtech.com Application Support: team2@carlingtech.com
Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com
|
4
MS-Series Circuit Breaker - Ordering Scheme
M S 1 B 14 615 C 1 C B A 0A A
8
9
10
11
12
13
1
2
3
4
5
6
7
Actuator Front
Legend
Plate
Bushing
Color
Voltage
Code
Agency
Approval
Series
Actuator Poles
Circuit
Frequency
& Delay
Current
Rating
Terminal
Color
Panel
Hardware
7 TERMINAL
1 SERIES
1
2
3
C
E
L
Push-On 0.250 Tab (QC)
M
Screw 8-32 (Upturned Lugs)
Screw 8-32 (Bus Type)
Screw Terminal M4 (Upturned Lugs)
Screw Terminal M4 (Bus Type)
Solder Lug
2 ACTUATOR
S
Sealed Toggle
3 POLES
8 ACTUATOR & MARKING COLOR
1
One
2
Two
3
Three
1
Dull Metallic
4 CIRCUIT
9 FRONT PANEL HARDWARE
1,2
A
B
M
9
Switch Only (no coil)
A
B
C
F
No Outer Panel Hardware
Hex Nut, Nickel Plated
(
)
Series Trip current
Series Trip (current) Aux switch .110 QC x 0.20 QC (silver contacts)
Series Trip (current) Aux switch .110 QC x 0.20 QC (gold contacts)
Hex Nut, Nickel Plated with Locking Ring
Panel Dress Nut, Nickel Plated
G
Panel Dress Nut, Nickel Plated with Locking Ring
5 FREQUENCY & DELAY
03 DC, 50/60 Hz, Switch Only
10 DC, Instantaneous
12 DC, Short
1
32 DC, 50/60 Hz Short
10 LEGEND PLATE
34 DC, 50/60 Hz Medium
62 50/60 Hz Short, Hi-Inrush
A
B
C
D
E
F
No Legend Plate
On-Off Vertical
On-Off Horizontal
I-O Vertical
4
4
14 DC, Medium
64 50/60 Hz Medium, Hi-Inrush
4
20 50/60 Hz Instantaneous
22 50/60 Hz Short
72 DC, Short, High-Inrush
4
74 DC, Medium, High-Inrush
I-O Horizontal
Dual Vertical
Dual Horizontal
4
4
24 50/60 Hz Medium
92 DC, 50/60 Hz Short, Hi-Inrush
94 DC, 50/60 Hz Medium, In-rush
30 DC, 50/60 Hz Instantaneous
G
6 CURRENT RATING (AMPERES)
11 BUSHING COLOR
CODE AMPERES
A
Nickel Plated / Multipole Version
220 0.200
225 0.250
230 0.300
235 0.350
240 0.400
245 0.450
250 0.500
255 0.550
260 0.600
265 0.650
270 0.700
275 0.750
280 0.800
285 0.850
290 0.900
295 0.950
410 1.00
512 1.25
415 1.50
517 1.75
420 2.00
522 2.25
425 2.50
527 2.75
430 3.00
435 3.50
440 4.00
445 4.50
450 5.00
455 5.50
460 6.00
465 6.50
470 7.00
475 7.50
480 8.00
485 8.50
490 9.00
495 9.50
610 10.00
710 10.50
611 11.00
711 11.50
612 12.00
712 12.50
613 13.00
614 14.00
615 15.00
616 16.00
617 17.00
717 17.50
618 18.00
619 19.00
620 20.00
622 22.00
624 24.00
625 25.00
630 30.00
12 VOLTAGE CODE
0A 65 VDC
0D 240 VAC
3
0C 120/240 VAC
3
0N 65 VDC / 120/240 VAC
17 65 VDC / 240 VAC
13 AGENCY APPROVAL
A
B
C
Without approvals
UL Recognized
UL & cUL Recognized
Notes:
1
2
3
4
Series code “A” only available with delay code “03”
Only available when tied to a protected pole
Requires a 2 or 3 pole device
Only available without agency approvals (Approval Code A)
Email: sales@carlingtech.com Application Support: team2@carlingtech.com
Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com
|
MS-Series Circuit Breaker - Form & Fit Drawings
5
Form & Fit
Notes:
1
2
All dimensions are in inches [millimeters].
Toleranceꢀ±.020ꢀ[.51]ꢀunlessꢀotherwiseꢀspecified.
Email: sales@carlingtech.com Application Support: team2@carlingtech.com
Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com
|
6
MS-Series Circuit Breaker - Delay Curve
Delay Curve
Dual Rated AC/DC
Instantaneous
Short
NO. 12, 22, 32, 62, 72, 92
Medium
Email: sales@carlingtech.com Application Support: team2@carlingtech.com
Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com
|
Reps & Contact
7
Authorized Sales Representatives
Click on the group name on the map below to find your local representative or visit
www.carlingtech.com/findarep.
Matera
W. Canada
Matera
E. Canada
MIDWEST
DM
MichigaNn ORTHERN
TEMCO Northwest
ND
SD
WA
OR
Hanna Lind Ltd.
MT
ME
VT
WI
Sierra
MN
Melody
NH
Emery
MI
LD. Allen MA
ID
Norris
NY
CT
WY
«
IA
IN
DM Assoc
OH East
PA
RI
Bridge Marketing
NE
KS
Pacent
TSI North
Omega Limited
Dy-tronix Inc.
DM
NJ
NV
IL
DE
Assoc
WV
MD
TSI
UT
CO
KY
VA
CA
MO
TN
NC
SC
Luscombe
Signal
OK
Engineering
WEST
Enterprises
AR
Pinnacle Marketing
AZ
NM
Sunbelt Components
MS
AL
GA
TX
SOUTHEAST
LA
Matrix
DM Mexico
South America
Mexico
ProRep
Solutions
FL
LATIN AMERICA
Europe
Middle East
Africa
Asia-Pacific
Oceania
Americas
About Carling
Founded in 1920, Carling Technologies is a leading manufacturer of electrical and electronic switches
and assemblies, circuit breakers, electronic controls, power distribution units, and multiplexed power
distribution systems. With four ISO registered manufacturing facilities and technical sales offices worldwide,
Carling Technologies Sales, Service and Engineering teams do much more than manufacture electrical
components, they engineer powerful solutions! To learn more about Carling please visit
www.carlingtech.com/company-profile.
To view all of Carling’s environmental, quality, health & safety certifications please visit
www.carlingtech.com/environmental-certifications
Email: sales@carlingtech.com Application Support: team2@carlingtech.com
Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com
Worldwide Headquarters
Carling Technologies, Inc.
60 Johnson Avenue, Plainville, CT 06062
Phone: 860.793.9281 Fax: 860.793.9231
@
Email: sales carlingtech.com
@
Northern Region Sales Office: nrsm carlingtech.com
@
Southeast Region Sales Office: sersm carlingtech.com
@
Midwest Region Sales Office: mrsm carlingtech.com
@
West Region Sales Office: wrsm carlingtech.com
@
Latin America Sales Office: larsm carlingtech.com
Asia-Pacific Headquarters
Carling Technologies, Asia-Pacific Ltd.,
Kowloon, Hong Kong
Phone: Int + 852-2737-2277 Fax: Int + 852-2736-9332
@
Email: sales carlingtech.com.hk
@
Shenzhen, China: shenzhen carlingtech.com
@
Shanghai, China: shanghai carlingtech.com
@
Pune, India: india carlingtech.com
@
Kaohsiung, Taiwan: taiwan carlingtech.com
@
Yokohama, Japan: japan carlingtech.com
|
|
Europe Middle East Africa Headquarters
Carling Technologies LTD
4 Airport Business Park, Exeter Airport,
Clyst Honiton, Exeter, Devon, EX5 2UL, UK
Phone: Int + 44 1392.364422 Fax: Int + 44 1392.364477
@
Email: ltd.sales carlingtech.com
@
Germany: gmbh carlingtech.com
@
France: sas carlingtech.com
www.carlingtech.com
REV_09_2015
相关型号:
©2020 ICPDF网 联系我们和版权申明